00-C-2804
b.
A battery charging alternator, with a rating of not less than 32
amperes.
c. Manufacturer's standard fuel filtration system.
d. Intake air cleaner shall be of the dry type, replaceable element.
e. Hour meter.
f. Engine governor with hand control to set and control any speed from
idle to maximum.
g. Lubricating oil pressure indicator.
h. Battery charge indicator.
i. Muffler.
j. Liquid quantity fuel indicator.
k. The fuel tank shall be of sufficient capacity for not less than 4
hours of normal operation.
l. The engine shall be provided with a weather-resistant housing of
heavy-gage sheet steel. The housing shall be removalbe or otherwise
designed tO permit engine removal and replacement.
m. Coolant temperature indicator (if liquid cooled).
3.7.6.2 Electic motor. The electric motor shall be 230\460V, 3 phase, 60
Hertz, ball bearing, fully enclosed, fan cooled, integral hp, temperature rise
55° Centigrade (C), and designed for heavy-duty use. The motor shall conform to
NEMA MG-1. The motor speed, hp, and torque characteristics shall be sufficient
to operate the conveyor under any of the requirements and tests specified
herein. Motor wiring and controls shall conform to applicable portions of NFPA
70. The motor shall be provided with a mounting bracket and shall be initially
wired for 460V.
3.7.6.2.1 Motor controller. A motor controller conforming to NEMA ICS-2,
and applicable portions of NFPA 70, shall be furnished. The motor controller
shall be mounted in a protected location. Overload and undervoltage protection
shall be provided. The controller shall be housed in a NEMA ICS-6 type No. 12
enclosure. The controller shall be equipped with dustproof and waterproof
connector to accommodate a power cable from an outside source.
3.7.6.2.2 ON-OFF Switch. The conveyor shall be furnished with an ON-OFF
switch for manually starting and stopping the electric motor. The switch shall
be mounted near the foot end of the conveyor and shall be accessible from the
ground when the conveyor is elevated to all operating positions.
3.7.6.2.3 Power cable. A 75-foot long power cable shall be provided.
The cable shall be four wire, of sufficient ampacity, type "SO" and conform to
UL 62. The cable shall be terminated on one end with a three pole, four wire,
locking type NEMA L16-30P plug, conforming to NEMA WD-6 and UL 498.
3.8 Mounting. The conveyor shall be mounted on a pneumatic-tired, two or
four wheeled axle assembly, and joined to a common steel frame of welded
construction. Wheels shall have ball or roller bearings protected from dust,
sand, and water.
Wheel and tires. Wheal and tire ratings shall conform to TRA
3.8.1
recommendations for the the and size of tires furnished. Tires shall be tube
or tubeless type with highway tread. Tires shall be of rated capacity at least
equal to the load imposed on each tire, measured at each wheel at the ground.
Tires shall be not less than 100 level quality and shall be of domestic make.
7
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business